Description
The Snow chair is produced with a single injection of polypropylene reinforced with glass fibre obtained by means of the latest generation of air moulding technology with neutral tones. For indoor use only.? Available in Black, Anthracite, Taupe, Red, Mango and White.
Features
- Stackable:?4 to 6 high
- Suitable for indoor use only
- Made of UV stabilised polypropylene reinforced with glass fibre
- Dimensions: W520 x D560 x H830 Seat Height 470
- Unit Weight: 4.4kg
- SWL: 150Kg
- Supplied assembled
- Weather resistant, UV Stabilised, Glass fibre reinforced
- Heavy Duty AFRDI Approved – Black
- Stocked in: Black, Red, Anthracite, Taupe, Mango, White
- Made in Europe
- Produced in accordance with ISO 14001:2015 Environmental Management System Certification
Please Note: Product Sizes, Weights & Colours may vary and are subject to change.
Tests Completed
1. Outdoor furniture - General safety requirements EN 581-1:2017
2. Seat and back static load test EN 1728:2012+AC:2013
3. Seat and back fatigue test EN 1728:2012+AC:2013
4. Leg forward static load test EN 1728:2012+AC:2013
5. Leg sideways static load test EN 1728:2012+AC:2013
6. Seat impact test EN 1728:2012+AC:2013
7. Stability - EN 1022:2005
Seat & Back Static Load Test
Seat Load (kg) | Back Force (kg) | Number of Cycles |
204 |
57 |
10 x 10s |
204 |
57 |
1 x 30 min
|
Seat Front Edge Static Load Test
Seat Load (kg) | Number of Cycles |
132 | 10 |
General Safety Requirements
- Edges of seat, back rest and arm rests rounded and chamfered
- All other parts: free from burrs, sharp edges and sharp points.
- Any load bearing part of furniture not come loose unintentionally
Tubular Components Safety Requirements
- Absence of tubular components with diameter > 7 mm and < 12 mm with a depth > 10 mm.
- Tubulars in contact with the floor are closed. Holes in them are allowed as long as they are < 7 mm or > 12 mm
Shear & Squeeze Points Safety Requirements
- Absence of shear and squeeze points, created by loads applied during normal use.
- Conformity to requirements of clause 5 of standard EN 581-1